One of my favorite holiday TV specials is Rudolf The Red-Nosed
Reindeer. I love the part where Hermey tames the Abominable Snowman by fixing
his toothache. It got me thinking about steam heating systems. (Yes, that’s the
weird way my mind works.) Like the Abominable they’re often misunderstood and
lonely.
Your steam heating system can seem mysterious and sometimes
even a little scary or creepy. This large hunk of metal sits in the dark
recesses of your basement making odd hissing, panting or clanging sounds. Every
so often it rumbles to life and sends heat upstairs to the rest of the house,
but mostly it’s the reason you don’t like going down “there.”
It doesn’t mean to be so scary. It’s just lonely and needs a
little love and understanding — like the Abominable. Once you get to know him,
you’ll realize he’s a softy at heart and he just wants to be helpful and
accepted.
If we’re going to get to know this monster, we should
probably start at the heart of the system. The boiler is where the heating
cycle begins and ends. In its simplest form, it’s a hollow block of cast iron
with a burner underneath. It’s partially filled with water that the burner
heats up to a boil (hence, why it’s a “boiler” and not a “furnace.”). When the
water starts to boil it creates steam. The steam exits the top of the boiler
through pipes that distribute the steam to all of the radiators in your house.
The radiators give up the heat of the steam to your rooms,
which cools the steam to the point that it condenses back to water in the
radiator. The water now drains back through pipes to the boiler and gets heated
back to steam in a cycle that continues until your house is warm enough and the
boiler shuts down until your thermostat calls for heat again.
The combustion byproducts are safely vented through the
chimney and out the roof. It’s a simple and elegant process that repeats itself
over and over for many years —making you warm and comfy and not asking for much
in return.
When things are working right it’s quiet and efficient. When
they’re not, it can be loud, uncomfortable, inefficient and just plain grumpy.
Like the Abominable, sometimes it needs some attention to keep it content.
We’ll talk more in future posts about some different types of
steam systems and some simple things you can do to keep your Bumble humble.
Happy New Year!
Heidronically yours,
Wayne

thank you for sharing your knowledge. I just purchased a home with two heating systems. 1 an oil FHW, and a gas/steam. I am going to give it a go with the "wet" heat. If I cant handle it I may add a zone to the oil FHW and use the radiators for that. Hoping there will be no leaks. I will be doing a lot of reading, so please keep writing. Thank you.
ReplyDeletethank you for sharing your knowledge. I just purchased a home with two heating systems. 1 an oil FHW, and a gas/steam. I am going to give it a go with the "wet" heat. If I cant handle it I may add a zone to the oil FHW and use the radiators for that. Hoping there will be no leaks. I will be doing a lot of reading, so please keep writing. Thank you.